Two cooling solutions, different installation approaches

Choosing the right TECO aquarium chiller involves more than matching a model to the size of your tank. The way the aquarium is configured, the available space and the required cooling performance all influence which solution is most suitable.

TECO AQUA offers two main ranges of aquarium chillers: TK in-line chillers and DI Drop-In chillers. Both are designed to maintain stable water temperatures in freshwater and marine aquariums, but they differ in how they are installed and how heat is exchanged.

Understanding these differences is the first step towards choosing the right cooling system for your aquarium.

TK vs Drop-In: what's the difference?

The main difference between the two TECO chiller ranges is how they interact with the aquarium's water circulation system.

  • TK in-line chillers are connected to the aquarium's hydraulic circuit. Water flows through the chiller, where heat is removed before the water returns to the tank.
  • DI Drop-In chillers use a titanium heat exchanger immersed directly in the water. Cooling takes place without connecting the refrigeration unit to the aquarium's plumbing.

Neither solution is inherently better than the other. Each offers specific advantages depending on the installation requirements, existing equipment and aquarium configuration.

TK chillers: integrated cooling for aquarium water circuits

The TECO TK range is designed for aquariums equipped with a suitable water circulation system.

An in-line chiller uses an internal heat exchanger to remove heat from the water passing through the unit. This configuration makes TK models particularly suitable for installations where the required hydraulic connections and water flow can be provided.

The range includes several models designed for different aquarium sizes and cooling requirements:

  • TK 150, TK 500 and TK 1000: compact solutions for smaller and medium-sized aquariums.
  • TK 2000: designed for larger aquarium systems, with a reference capacity of up to 2,000 L.
  • TK 2000L: a specialized model developed for applications requiring lower water temperatures.
  • TK 3000 and TK 9000: higher-capacity solutions for large aquariums and professional installations.

Selected TK models are also available with an integrated heater, providing additional temperature management options.

Explore the TECO TK aquarium chiller range to compare models, technical specifications and operating parameters.

DI Drop-In chillers: cooling without plumbing modifications

The TECO DI Drop-In range offers a different approach to aquarium cooling, designed to simplify installation and integration into existing systems.

Instead of circulating water through the refrigeration unit, a titanium heat exchanger is placed directly inside the sump or technical tank.

This configuration eliminates the need for additional hydraulic connections or a dedicated pump to circulate water through the chiller. The heat exchanger must remain fully submerged, with adequate water movement around it to ensure effective heat transfer.

Drop-In chillers are particularly useful for:

  • Established aquariums, where modifying the existing plumbing would be difficult or impractical.
  • Sumps and technical tanks, where the heat exchanger can be positioned directly in the water.
  • DIY and customized setups, requiring greater installation flexibility.
  • Temporary or emergency installations, where cooling needs to be introduced without major modifications.

The TECO Drop-In range includes three models:

  • DI 500: for systems up to 500 L.
  • DI 1000: for systems up to 1,000 L.
  • DI 2000: for systems up to 2,000 L.

These reference capacities depend on specific operating conditions and should not be considered absolute limits for every installation.

Discover the TECO Drop-In chiller range and its installation advantages.

How to choose the right TECO chiller model

Once you have identified the most suitable installation type, the next step is to evaluate the actual cooling requirements.

Aquarium volume alone is not enough to determine the correct chiller size. The cooling load depends on several factors, including:

  • Total water volume: including the main aquarium, sump and other connected tanks.
  • Ambient temperature: particularly the highest temperature expected in the installation area.
  • Desired water temperature: the difference between the surrounding environment and the target temperature affects cooling demand.
  • Equipment heat load: lighting, pumps and other devices can contribute additional heat.
  • Installation conditions: available ventilation, insulation and water circulation influence overall performance.

Published tank capacities are based on defined test conditions. For example, standard TK capacity ratings generally refer to an ambient temperature of 30°C and a water temperature of 25°C. Drop-In ratings also specify a heat load of 0.2 W/L.

Actual performance may therefore vary from one aquarium to another, even when the total water volume is identical.

To support model selection, TECO AQUA provides a dedicated Chiller Sizing Calculator , which considers aquarium dimensions, temperatures and additional system parameters.

The calculator provides a useful starting point, while the technical datasheets should always be consulted to verify the selected model's operating requirements.

Choosing between TK and Drop-In: what matters most?

The decision between a TK and a DI model should begin with the aquarium's installation requirements.

A TK in-line chiller may be the preferred option when the aquarium has an accessible hydraulic circuit, suitable water flow and space for the necessary connections.

A DI Drop-In chiller may be more practical when the system is already operating, plumbing modifications need to be avoided or a flexible cooling solution is required.

In both cases, correct sizing, adequate ventilation and suitable operating conditions remain essential for reliable temperature control.

With the TK and Drop-In ranges, TECO AQUA provides different ways to integrate professional cooling technology into aquariums, from compact home installations to more complex systems.

Frequently asked questions about TECO chillers

What is the difference between a TECO TK chiller and a Drop-In chiller?

A TK chiller connects to the aquarium's water circulation circuit and cools water as it passes through the unit. A DI Drop-In chiller uses a submerged titanium heat exchanger, eliminating the need for water-line connections to the refrigeration unit.

Does a TECO Drop-In chiller require a separate water pump?

No dedicated pump is needed to circulate water through the chiller. However, the titanium heat exchanger must remain fully submerged, and adequate water movement around it is necessary for effective cooling.

Can TECO chillers be used in saltwater and freshwater aquariums?

Yes. Both TK and DI ranges are designed for freshwater and marine aquarium applications. Their titanium heat exchangers provide compatibility with aquatic environments.

Can I choose a TECO chiller based only on aquarium capacity?

No. While the nominal capacity provides an initial reference, the correct model also depends on ambient temperature, desired water temperature, equipment heat load and installation conditions.

Which TECO chiller is best for an existing aquarium?

It depends on the aquarium's configuration. If an existing water circuit can accommodate the required connections, a TK model may be suitable. If plumbing modifications are difficult, a DI Drop-In chiller can provide a more straightforward installation alternative.

Find the right cooling solution for your aquarium

Every aquarium has specific cooling requirements. Explore the TECO AQUA chiller ranges, compare their technical specifications and use our Chiller Sizing Calculator to identify the most suitable solution for your setup.

Explore TECO aquarium chillers  |  Discover Drop-In chillers  |  Calculate your chiller size

CONTACT US

Tel.: +39 0544 408333
Mail: info@tecoonline.com

COMPANY

Indirizzo
TECO S.r.l
Via G. Ricci Curbastro 8
48124 Fornace Zarattini
Ravenna – Italy